Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesth Essays Res ; 12(1): 119-123, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29628566

RESUMO

INTRODUCTION: In the past 25 years with the development of various supraglottic airway devices, the armamentarium for airway management has increased. In our study, the laryngeal mask airway (LMA)-ProSeal is compared with the LMA-Classic with respect to as follows: (a) Ease of insertion and number of insertion attempts, (b) Device positional stability and possible oropharyngeal leak, (c) Airway trauma, and (d) Hemodynamic changes; in children aged 3-15 years undergoing elective surgery under general anesthesia, hypothesizing that these would be different. MATERIALS AND METHODS: Sixty consecutive American Society of Anesthesiologists Physical Status Classes I and II children aged 3-15 years and weighing 5-45 kg undergoing elective surgery in the supine position were randomized for airway management with the LMA-Classic or LMA-ProSeal. RESULTS: Size of the LMA used in both LMA-Classic and LMA-ProSeal was 1.5, 2, and 2.5 and was statistically nonsignificant. There was no difference between LMA-Classic and LMA-ProSeal with regard to ease of insertion, number of attempts for insertion, device positional stability, airway trauma and hemodynamic changes. CONCLUSIONS: The complications of usage of the LMA are minimal and similar in both the devices. The LMA-ProSeal has advantages over LMA-classic such as the placement of gastric tube, adequate ventilation, and oxygenation without any gastric distension.

2.
Indian J Anaesth ; 62(3): 173-181, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29643550

RESUMO

BACKGROUND AND AIMS: Airway used in prone position should be efficacious and safe. The Streamlined Liner of the Pharynx Airway (SLIPA™) and Laryngeal Mask Airway-ProSeal (PLMA) provide better airway seal and protection against aspiration. We planned to evaluate the performance of SLIPA™, PLMA and endotracheal tube (ETT) in prone position. METHODS: 114 adult patients undergoing elective surgery in prone position under general anaesthesia were randomised into Group-T (ETT), Group-S (SLIPA™) and Group-P (PLMA). Airways were inserted in supine position and patients turned prone subsequently. Airway characteristics, ventilatory parameters and complications were noted. One-way analysis of variance, Mann-Whitney U-test and Chi-square or Fisher's exact test were used. RESULTS: Tidal volumes, peak airway pressure and compliance were comparable at all times. Leak pressure was significantly higher (P < 0.001) in Group-T (mean leak pressure = 40 cmH2O) when compared to Group-S and Group-P at all the times of recording, and there was no significant difference between Group-S and Group-P. The number of patients requiring airway/neck manipulation in prone position was significantly higher (P < 0.001) in Group-S (19 [55.9%]) when the three groups were compared (none in Group-T) and in comparison with Group-P (5 [14.7%], P < 0.001). On airway removal, the incidence of complications and airway reaction was significantly higher in Group-T. Group-S had a significantly higher incidence of dysphagia at 2 h postoperatively. CONCLUSION: ETT was most efficacious. SLIPA™ and PLMA were efficacious, safe and less stimulating to the airway during removal. More patients required SLIPA™ airway/neck manipulation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...